Fire safety PLC processor Controller DC brushless Motor 24V Automatic Sliding Door
CA-3000 commercial automatic sliding glass doors
Outstanding performance
Taiwan design structure
Multi-functional Switch
Security
Fire safety
NEW STYLE TAIWAN AUTOMATIC SLIDING DOOR
The microcomputer controller has self learning function; The drive divice works smoothly, it's safe and reliable; The comprehensive functions can satisfy the the individual needs.
Motor, controller and belt pulley are hanging in the guide rail top, gives the larger space for big hangers to drive smoothly, there is very soft noise.
Managers can realize the automatic door five functions conveniently: lock, keep opening, single direction entrance, half open, automatic operation.
The safety beam photocell will keep the door open to offer security for the passers-by.
In an emergency, press the abrupt stop switch, the door will stop immediately, security is fully guaranteed.
The door will open automatically when fire happens, it helps to win time for escape.
Technical specifications:
Door Configuration: Single leaf , Double leaf
Door leaf weight limit: 1x200kgs,2x150kgs
Clean open width: 600-1800mm,1000-3000mm
Power supply: AC 220V±10%, 50-60Hz 2A
AC 80V±10% 50-60Hz 2A
Power consumption: 75W
Opening speed: 200-500mm/s (adjustable)
Closing speed: 200-500mm/s (adjustable)
Hold -open time: 0-9S
Manual force: <30N, <40N
Sliding noise: ≤ 55Db
Environment temperature: -20°C~+55°C
Tempered glass is one of two kinds of safety glass regularly used in applications in which standard glass could pose a potential danger. Tempered glass is four to five times stronger than standard glass and does not break into sharp shards when it fails. Tempered glass is manufactured through a process of extreme heating and rapid cooling, making it harder than normal glass.
laminated glass is a type of safety glass that holds together when the glass shattered. in the events of breaking ,it is held in place hy an interlayer ,typically of PVB ,between its two or more layers of glass. the interlayer keeps the layers of glass bonded even when broken ,and its high strength prevents the glass from breaking up into large sharpe pieces ,this produces a characteristic "spider web " cracking pattern when the impact is enough to completely pierce the glass.
Application tempered glass normally used when there is a possibility of human impact or where the glass could fall if shattered. skylight glazing and automobile windshields typically use tempered glass
Particulars &Specification of ITD-SF-TGK0011 commercial automatic sliding glass doors
Name of product item & Mdoel NO. |
CA-3000 commercial automatic sliding glass doors |
|
Structure |
solid |
|
size |
5mm:1650x2200,6mm:2134x3660,8mm:1650x3300,1700x3660,2440x3660 |
|
|
10mm:1850x3660,1950x3660,2134x3300,1650x3660 | |
Thickness |
3mm--12mm |
|